For spas and hot tubs, the maximum length shall be 6 feet. Limited to use at pool, spa or hot tub equipment where flexibility is necessary.Permitted only for existing installations in accordance with the exception to Section E4205.6.Metal conduit shall be constructed of brass or other approved corrosion-resistant metal.For all wiring methods, see Section E4205 for equipment grounding conductor requirements.Indoor spas and hot tubs, hydromassage bathtubs, and other pool, spa or hot tub associated equipment: from branch circuit OCPD to equipment Packaged or self-contained outdoor spas and hot tubs without underwater luminaire: from branch circuit OCPD to spa or hot tub Packaged or self-contained outdoor spas and hot tubs with underwater luminaire: from branch circuit OCPD to spa or hot tub Pool-associated motors: from branch circuit OCPD to motor Wet-niche and no-niche luminaires: from deck or junction box to forming shellÄry niche: from branch circuit OCPD to luminaires Wet-niche and no-niche luminaires: from branch circuit OCPD to deck or junction box Panelboard(s) that supply pool equipment: from service equipment to panelboard TABLE E4202.1 ALLOWABLE APPLICATIONS FOR WIRING METHODS a, b, c, d, e, f, g, h, l WIRING LOCATION OR PURPOSE (Application allowed where marked with an "A") Storable swimming pools shall comply with Section E4207. Wiring methods used in conjunction with permanently installed swimming pools, spas, hot tubs or hydromassage bathtubs shall be installed in accordance with Table E4202.1 and Chapter 38 except as otherwise stated in this section.